西门子PLC模块CPU314C-2PN/DP

简要描述:西门子PLC模块CPU314C-2PN/DP,西门子S7-300CPU314C-2PN/DP,SIMATIC S7-300, CPU 314C-2PN/DP 紧凑型CPU带有192 KB工作存储区, 24 数字量输入/16 数字量输出, 4模拟量输入, 2模拟量输出, 1 PT100, 4 快速计数器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太网 PROFIN

  • 产品型号:
  • 厂商性质:代理商
  • 更新时间:2017-09-17
  • 访  问  量:1350

详细介绍

西门子PLC模块CPU314C-2PN/DP,西门子S7-300CPU314C-2PN/DP,西门子CPU314C-2PN/DP,CPU314C-2PN/DP,西门子S7-300CPU314C-2PN/DP可编程控制器

订货号:6ES7314-6EH04-0AB0

SIMATIC S7-300, CPU 314C-2PN/DP 紧凑型CPU带有192 KB工作存储区, 24 数字量输入/16 数字量输出, 4模拟量输入, 2模拟量输出, 1 PT100, 4 快速计数器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太网 PROFINET, 含 2个 PORT SWITCH, 集成 24V DC 电源, FRONT C

德国* 现货销售 质保一年 欢迎询价

SIEMENS上海翰粤自动化系统有限公司

 

上海翰粤公司在经营活动中精益求精,具备如下业务优势:
SIEMENS 可编程控制器
  1、 SIMATIC S7 系列PLC:S7-200、S7-1200、S7-300、S7-400、ET-200
  2、 逻辑控制模块 LOGO!230RC、230RCO、230RCL、24RC、24RCL等
  3、 SITOP直流电源 24V DC 1.3A、2.5A、3A、5A、10A、20A、40A可并联.

4、HMI 触摸屏TD200 TD400C K-TP OP177 TP177,MP277 MP377,
SIEMENS 交、直流传动装置
  1、 交流变频器 MICROMASTER系列:MM420、MM430、MM440、G110、G120.  

  MIDASTER系列:MDV
  2、全数字直流调速装置 6RA23、6RA24、6RA28、6RA70、6SE70系列

SIEMENS 数控 伺服

SINUMERIK:801、802S 、802D、802D SL、810D、840D、611U、S120

系统及伺报电机,力矩电机,直线电机,伺服驱动等备件销售。

西门子PLC模块CPU314C-2PN/DP,西门子S7-300CPU314C-2PN/DP, 概述

  • 带集成的数字量和模拟量输入/输出的紧凑型 CPU
  • 对二进制和浮点数运算具有较高的处理能力
  • 用于通过 PROFIBUS 和 PROFINET 进行分布式 I/O 连接。
  • 组合 MPI/PROFIBUS DP-主/从接口
  • 用于 2 端口交换机的 PROFINET 接口
  • PROFINET I/O 控制器,用于在PROFINET上运行分布式I/O
  • PROFINET I-Device,用于连接作为智能 PROFINET 设备、带 SIMATIC 或第三方 PROFINET I/O 控制器的 CPU
  • 在PROFINET上实现基于组件的自动化(CBA)
  • PROFINET 代理,用于基于组件的自动化(CBA)中的 PROFIBUS DP 智能设备
  • 集成 Web 服务器,带有创建用户定义的 Web 站点的选项
  • 经由 PROFIBUS 的等时同步模式

CPU 运行需要 SIMATIC 微存储卡(MMC)。

,西门子S7-300CPU314C-2PN/DP 应用领域

CPU 314C-2 DP 是紧凑型 CPU,适合安装在分布式结构中。通过其扩展工作存储器,该紧凑型CPU也适用于中等规模的应用。集成的数字量和模拟量输入和输出可与过程信号直接连接。集成的 的PROFIBUS DP 主站/从站以及 PROFINET IO 控制器/I-设备接口,用于 PROFIBUS 和 PROFINET 的分布式连接。这使得 CPU 314C-2 PN/DP 可作为进行快速处理的分布式单元使用,也可作为 PROFIBUS 和 PROFINET 系统中具有低端现场总线系统的上位控制器。

集成技术工程的其他用途包括:

  • 计数
  • 频率测量
  • 周期测量
  • 脉宽调制
  • PID 控制
  • 定位控制

,西门子S7-300CPU314C-2PN/DP

CPU 314C-2 DP 安装有:

  • 微处理器;
    每条二进制指令执行时间约60ns,每条浮点数运行指令约0.59µs.
  • 扩展存储器;
    与执行相关的程序段的 192 KB 高速 RAM(相当于约 64 K 指令)可以为用户程序提供足够的空间;
    SIMATIC 微型存储卡(zui大 8 MB)作为程序的装载存储器,还允许将项目(包括符号和注释)存储在 CPU 中。
  • 灵活的扩展能力
    多达 31 个模块,(4排结构)
  • 多点接口(MPI);
    集成的 MPI 接口zui多可以同时建立与 S7-300/400 或编程设备、PC、OP 的 12 条连接。在这些连接中,总要分别为 PG 和 OP 各保留一个连接。通过“全局数据通讯”,MPI可以用来建立zui多16个CPU组成的简单网络。
  • PROFIBUS DP 接口:
    带有 PROFIBUS DP 主/从接口的 CPU 314C-2 DP 可以用来建立高速、易用的分布式自动化系统。 对用户来说,分布式I/O单元可作为一个集中式单元来处理(相同的组态、编址和编程).
  • 以太网接口;
    CPU 314C-2 PN/DP 的第 2 个内置接口是一个基于以太网 TCP/IP 的 PROFINET 接口,带有双端口交换机。
    它支持下列协议:
    • S7通讯用于在SIMATIC控制器间进行数据交换;
    • 用于通过 STEP 7 编程、调试和诊断的编程器/OP通讯
    • 与HMI和SCADA连接的PG/OP通讯;
    • 通过 PROFINET 进行的开放式 TCP/IP、UDP 和 ISO-on-TCP (RFC1006) 通讯
    • SIMATIC NET OPC-Server用于与其它控制器以及CPU自带的I/O设备进行通讯
  • 内置输入/输出;
    24路数字量输入(所有输入都可用作中断处理)和16路数字量输出,以及5个模拟量输入和2个模拟量输出,使得CPU 314C-2 DP是一款*的控制器。

,西门子S7-300CPU314C-2PN/DP 设计

  • 口令保护;
    用户程序使用密码保护,可防止非法访问。
  • 块加密
    相关功能 (FC) 和 功能块 (FB) 可以加密的方式存储于 CPU 以保护专门知识应用。
  • 诊断缓冲;
    zui后500个故障和中断事件保存在该缓冲区中,供诊断使用。 其中,保留zui后 100 个条目
  • 免维护的数据后备;
    如果发生断电,则可通过 CPU 将所有数据(zui多达 64 KB)自动写入到 SIMATIC 微型存储卡(MMC 卡)上,且将在再次通电时保持不变。

可参数化的特性

可以使用 STEP 7 对 S7 的组态、属性以及CPU的响应进行参数设置:

  • 概要:
    定义名称、系统号和位置号
  • 启动;
    定义 CPU 的启动特性和监视时间
  • 同步循环中断;
    设置 IO 系统编号、过程映像分区编号和延时
  • 循环/时钟存储器;
    定义zui大的扫循环描时间和负载设置时钟存储器地址
  • 记忆性;
    定义具有保持功能的存储位、计数器、定时器和数据块的数量
  • 日时钟中断
    设定起始日期、起始时间和间隔周期
  • 周期中断;
    周期设定
  • 系统诊断;
    定义诊断消息的处理和范围。
  • 时钟;
    设定 AS 内或 MPI 上的同步方式
  • 防护等级;
    说明程序和数据访问授权。
  • 通讯;
    保留连接源
  • Web;
    CPU 的 Web 服务器设置
  • MPI/PROFIBUS-DP 接口:
    设置接口类型。定义节点地址。对操作模式进行参数化,并组态使用 PROFIBUS DP 时的传输区对时间同步进行参数化
  • PROFINET 接口;
    地址设定。对 PROFINET 属性、智能设备功能、PROFINET 上的同步类型、使用 NTP 步骤的时间同步、介质冗余和 KeepAlive 功能进行参数化。参数化端口 1 和端口 2
  • 数字量输入/输出
    地址设定,输入继电器和过程中断
  • 模拟输入/输出
    设定地址
    输入的情况下:设定温度单元,测量种类,测量范围,以及接口频率
    输出的情况下:设定输出类别和输出范围
  • 集成功能“计数器” 
    设定地址,以及 “连续计数”“单次计数”“周期计数”“频率测量”和“脉宽调制”模式下的参数分配
  • 集成功能“定位器” 
    设定地址,“数字输出定位”和“模拟输出定位”参数
  • 集成功能“规则”

显示功能与信息功能

  • 状态和故障指示;
    LED 指示硬件、编程、定时或 I/O 故障以及操作状态(如 RUN、STOP 和 Start-up)。
  • 测试功能;
    可使用编程器显示程序执行过程中的信号状态,可以不通过用户程序而修改过程变量,以及输出堆栈内容。
  • 信息功能;
    您可以使用编程器以纯文本的形式获取 CPU 存储容量和操作模式、工作存储器和装载存储器的当前利用率以及当前循环时间和诊断缓冲区内容的相关信息。

集成的通讯功能

  • 编程器/OP 通讯
  • 全局数据通讯
  • S7 基本通讯
  • S7 通讯
  • 路由
  • 数据记录路径
  • PROFIBUS DP 主站/从站
  • 通过 TCP/IP、ISO-on-TCP 和 UDP 进行开放式通讯
  • PROFINET IO 控制器
  • PROFINET 智能设备
  • PROFINET CBA(基于组件的自动化)
  • Web 服务器

集成功能

  • 计数器;
    4 个计数器(zui高 60 kHz),具有独立方向的比较器,可直接连接到 24V 增量编码器。
  • 4通道频率测量;
    允许进行频率测量(高达 60 kHz),例如,测量轴速或吞吐量(每个测量周期内的件数)。
  • 周期测量
    用于获取并处理计数脉冲,频率zui高为 1 KHz
  • 脉宽调制;
    4个输出可直接连接控制阀、执行器、开关设备、加热装置等,例如采样频率为 2.5 kHz。 可设置周期长度并可在运行时修改占空比。
  • 定位控制
    集成在操作系统中的SFB可通过2路数字量输出或1个模拟量输出对1个轴进行定位控制。
  • 报警输入(所有数字量输入);
    报警输入可以检测过程事件,并在zui短的时间内触发响应。

,西门子S7-300CPU314C-2PN/DP 技术规格

 

6ES7 314-6EH04-0AB0

General information

 

Hardware product version

01

Firmware version

V3.3

Supply voltage

 

24 V DC

Yes

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

Mains buffering

 

  • Mains/voltage failure stored energy time

5 ms

  • Repeat rate, min.

1 s

Digital inputs

 

  • Load voltage L+

 

    • Rated value (DC)

24 V

    • Reverse polarity protection

Yes

Digital outputs

 

  • Load voltage L+

 

    • Rated value (DC)

24 V

    • Reverse polarity protection

No

Input current

 

Current consumption (rated value)

850 mA

Current consumption (in no-load operation), typ.

190 mA

Inrush current, typ.

5 A

I²t

0.7 A²·s

from supply voltage L+, max.

850 mA

Digital inputs

 

  • from load voltage L+ (without load), max.

80 mA

Digital outputs

 

  • from load voltage L+, max.

50 mA

Power losses

 

Power loss, typ.

14 W

Memory

 

Type of memory

other

Work memory

 

  • integrated

192 kbyte

  • expandable

No

  • Size of retentive memory for retentive data blocks

64 kbyte

Load memory

 

  • pluggable (MMC)

Yes

  • pluggable (MMC), max.

8 Mbyte

  • Data management on MMC (after last programming), min.

10 a

Backup

 

  • present

Yes

  • without battery

Yes; Program and data

CPU processing times

 

for bit operations, typ.

0.06 µs

for word operations, typ.

0.12 µs

for fixed point arithmetic, typ.

0.16 µs

for floating point arithmetic, typ.

0.59 µs

CPU-blocks

 

Number of blocks (total)

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

 

  • Number, max.

1 024

  • Size, max.

64 kbyte

FB

 

  • Number, max.

1 024

  • Size, max.

64 kbyte

FC

 

  • Number, max.

1 024; Number range: 0 to 7999

  • Size, max.

64 kbyte

OB

 

  • Description

see instruction list

  • Size, max.

64 kbyte

  • Number of free cycle OBs

1

  • Number of time alarm OBs

1

  • Number of delay alarm OBs

2

  • Number of time interrupt OBs

4

  • Number of process alarm OBs

1

  • Number of DPV1 alarm OBs

3; OB 55, 56, 57

  • Number isochronous mode OBs

1; OB 61; only for PROFINET

  • Number of startup OBs

1

  • Number of asynchronous error OBs

6

  • Number of synchronous error OBs

2

Nesting depth

 

  • per priority class

16

  • additional within an error OB

4

Counters, timers and their retentivity

 

S7 counter

 

  • Number

256

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

255

    • preset

Z 0 to Z 7

  • Counting range

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • Number

256

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

255

    • preset

No retentivity

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

retentive data area, total

All, max. 64 KB

Flag

 

  • Number, max.

256 byte

  • Retentivity available

Yes; MB 0 to MB 255

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8; 1 memory byte

Data blocks

 

  • Number, max.

1 024; Number range: 1 to 16000

  • Size, max.

64 kbyte

  • Retentivity adjustable

Yes; via non-retain property on DB

  • Retentivity preset

Yes

Local data

 

  • per priority class, max.

32 kbyte; Max. 2048 bytes per block

Address area

 

I/O address area

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • of which, distributed

 

    • Inputs

2 003 byte

    • Outputs

2 010 byte

Process image

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • Inputs, adjustable

2 048 byte

  • Outputs, adjustable

2 048 byte

  • Inputs, default

256 byte

  • Outputs, default

256 byte

  • Default addresses of the integrated channels

 

    • Digital inputs

136.0 to 138.7

    • Digital outputs

136.0 to 137.7

    • Analog inputs

800 to 809

    • Analog outputs

800 to 803

Subprocess images

 

  • Number of subprocess images, max.

1; With PROFINET IO, the length of the user data is limited to 1600 bytes

Digital channels

 

  • Inputs

16 048

  • Outputs

16 096

  • Inputs, of which central

1 016

  • Outputs, of which central

1 008

Analog channels

 

  • Inputs

1 006

  • Outputs

1 007

  • Inputs, of which central

253

  • Outputs, of which central

250

Hardware configuration

 

Expansion devices, max.

3

Number of DP masters

 

  • integrated

1

  • via CP

4

Number of operable FMs and CPs (recommended)

 

  • FM

8

  • CP, point-to-point

8

  • CP, LAN

10

Rack

 

  • Racks, max.

4

  • Modules per rack, max.

8; In rack 3 max. 7

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

  • Deviation per day, max.

10 s; Typ.: 2 s

  • Backup time

6 wk; At 40 °C ambient temperature

  • Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

 

  • Number

1

  • Number/Number range

0

  • Range of values

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

  • retentive

Yes; Must be restarted at each restart

Clock synchronization

 

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes; With DP slave only slave clock

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

  • on Ethernet via NTP

Yes; as client

Digital inputs

 

Number of digital inputs

24

  • of which, inputs usable for technological functions

16

integrated channels (DI)

24

Input characteristic curve in accordance with IEC 61131, type 1

Yes

Number of simultaneously controllable inputs

 

  • horizontal installation

 

    • up to 40 °C, max.

24

    • up to 60 °C, max.

12

  • vertical installation

 

    • up to 40 °C, max.

12

Input voltage

 

  • Rated value, DC

24 V

  • for signal "0"

-3 to +5 V

  • for signal "1"

15 to 30 V

Input current

 

  • for signal "1", typ.

8 mA

Input delay (for rated value of input voltage)

 

  • for standard inputs

 

    • Parameterizable

Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)

    • Rated value

3 ms

  • for counter/technological functions

 

    • at "0" to "1", max.

8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency

Cable length

 

  • Cable length, shielded, max.

1 000 m

  • Cable length unshielded, max.

600 m

  • Technological functions

 

    • shielded, max.

50 m; at maximum count frequency

    • Unshielded, max.

not allowed

  • Standard DI

 

    • shielded, max.

1 000 m

    • Unshielded, max.

600 m

Digital outputs

 

Number of digital outputs

16

  • of which high-speed outputs

4; Notice: You cannot connect the fast outputs of your CPU in parallel

integrated channels (DO)

16

Short-circuit protection

Yes; Clocked electronically

  • Response threshold, typ.

1 A

Limitation of inductive shutdown voltage to

L+ (-48 V)

Controlling a digital input

Yes

Switching capacity of the outputs

 

  • Lamp load, max.

5 W

Load resistance range

 

  • lower limit

48 Ω

  • upper limit

4 kΩ

Output voltage

 

  • for signal "1", min.

L+ (-0.8 V)

Output current

 

  • for signal "1" rated value

500 mA

  • for signal "1" permissible range, min.

5 mA

  • for signal "1" permissible range, max.

0.6 A

  • for signal "1" minimum load current

5 mA

  • for signal "0" residual current, max.

0.5 mA

Parallel switching of 2 outputs

 

  • for increased power

No

  • for redundant control of a load

Yes

Switching frequency

 

  • with resistive load, max.

100 Hz

  • with inductive load, max.

0.5 Hz

  • on lamp load, max.

100 Hz

  • of the pulse outputs, with resistive load, max.

2.5 kHz

Aggregate current of outputs (per group)

 

  • horizontal installation

 

    • up to 40 °C, max.

3 A

    • up to 60 °C, max.

2 A

  • vertical installation

 

    • up to 40 °C, max.

2 A

Cable length

 

  • Cable length, shielded, max.

1 000 m

  • Cable length unshielded, max.

600 m

Analog inputs

 

Number of analog inputs

5

Integrated channels (AI)

5; 4 x current/voltage, 1 x resistance

Number of analog inputs for voltage/current measurement

4

Number of analog inputs for resistance/resistance thermometer measurement

1

permissible input frequency for current input (destruction limit), max.

5 V

permissible input voltage for voltage input (destruction limit), max.

30 V; Permanent

permissible input current for voltage input (destruction limit), max.

0.5 mA

permissible input current for current input (destruction limit), max.

50 mA; Permanent

Technical unit for temperature measurement adjustable

Yes; Degrees Celsius / degrees Fahrenheit / Kelvin

Input ranges

 

  • Voltage

Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ

  • Current

Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω

  • Resistance thermometer

Yes; Pt 100 / 10 MΩ

  • Resistance

Yes; 0 Ω to 600 Ω / 10 MΩ

Input ranges (rated values), voltages

 

  • 0 to +10 V

Yes

  • Input resistance (0 to 10 V)

100 kΩ

Input ranges (rated values), currents

 

  • 0 to 20 mA

Yes

  • Input resistance (0 to 20 mA)

100 Ω

  • -20 to +20 mA

Yes

  • Input resistance (-20 to +20 mA)

100 Ω

  • 4 to 20 mA

Yes

  • Input resistance (4 to 20 mA)

100 Ω

Input ranges (rated values), resistance thermometers

 

  • Pt 100

Yes

  • Input resistance (Pt 100)

10 MΩ

Input ranges (rated values), resistors

 

  • No-Load voltage, typ.

3.3 V

  • Measured current, typ.

1,25 mA

  • 0 to 600 ohms

Yes

  • Input resistance (0 to 600 ohms)

10 MΩ

Thermocouple (TC)

 

  • Temperature compensation

 

    • Parameterizable

No

Characteristic linearization

 

  • Parameterizable

Yes; by software

    • for resistance thermometer

Pt 100

Cable length

 

  • Cable length, shielded, max.

100 m

Analog outputs

 

Number of analog outputs

2

Integrated channels (AO)

2

Voltage output, short-circuit protection

Yes

Voltage output, short-circuit current, max.

55 mA

Current output, no-load voltage, max.

14 V

Output ranges, voltage

 

  • 0 to 10 V

Yes

  • -10 to +10 V

Yes

Output ranges, current

 

  • 0 to 20 mA

Yes

  • -20 to +20 mA

Yes

  • 4 to 20 mA

Yes

Connection of actuators

 

  • for voltage output two-wire connection

Yes; Without compensation of the line resistances

  • for voltage output four-wire connection

No

  • for current output two-wire connection

Yes

Load impedance (in rated range of output)

 

  • with voltage outputs, min.

1 kΩ

  • with voltage outputs, capacitive load, max.

0.1 µF

  • with current outputs, max.

300 Ω

  • with current outputs, inductive load, max.

0.1 mH

Destruction limits against externally applied voltages and currents

 

  • Voltages at the outputs towards MANA

16 V; Permanent

  • Current, max.

50 mA; Permanent

Cable length

 

  • Cable length, shielded, max.

200 m

Analog value creation

 

Measurement principle

Actual value encryption (successive approximation)

Integrations and conversion time/resolution per channel

 

  • Resolution with overrange (bit including sign), max.

12 bit

  • Integration time, parameterizable

Yes; 16.6 / 20 ms

  • permissible input frequency, max.

400 Hz

  • Interference voltage suppression for interference frequency f1 in Hz

60 / 50 Hz

  • Conversion time (per channel)

1 ms

  • Time constant of the input filter

0.38 ms

  • Basic execution time of the module (all channels released)

1 ms

Settling time

 

  • for resistive load

0.6 ms

  • for capacitive load

1 ms

  • for inductive load

0.5 ms

Encoder

 

Connection of signal encoders

 

  • for voltage measurement

Yes

  • for current measurement as 2-wire transducer

Yes; with external supply

  • for current measurement as 4-wire transducer

Yes

  • for resistance measurement with two-wire connection

Yes; Without compensation of the line resistances

  • for resistance measurement with three-wire connection

No

  • for resistance measurement with four-wire connection

No

Connectable encoders

 

  • 2-wire sensor

Yes

    • Permissible quiescent current (2-wire sensor), max.

1.5 mA

Errors/accuracies

 

Temperature error (relative to input range), (+/-)

0.006 %/K

Crosstalk between the inputs, min.

60 dB

Repeat accuracy in steady state at 25 °C (relative to input area), (+/-)

0.06 %

Output ripple (based on output area, bandwidth 0 to 50 kHz), (+/-)

0.1 %

Linearity error (relative to output range), (+/-)

0.15 %

Temperature error (relative to output range), (+/-)

0.01 %/K

Crosstalk between the outputs, min.

60 dB

Repeat accuracy in steady state at 25 °C (relative to output area), (+/-)

0.06 %

Operational limit in overall temperature range

 

  • Voltage, relative to input area, (+/-)

1 %

  • Current, relative to input area, (+/-)

1 %

  • Resistance, relative to input area, (+/-)

1 %

  • Voltage, relative to output area, (+/-)

1 %

  • Current, relative to output area, (+/-)

1 %

Basic error limit (operational limit at 25 °C)

 

  • Voltage, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.06 %

  • Current, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.06 %

  • Resistance, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.2%

  • Resistance thermometer, relative to input area, (+/-)

0.8 %

  • Voltage, relative to output area, (+/-)

0.8 %

  • Current, relative to output area, (+/-)

0.8 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

  • Series mode interference (peak value of interference < rated value of input range), min.

30 dB

  • Common mode interference, min.

40 dB

Interfaces

 

Number of USB interfaces

0

Number of parallel interfaces

0

Number of 20 mA interfaces (TTY)

0

Number of RS 232 interfaces

0

Number of RS 422 interfaces

0

Number of other interfaces

1; Ethernet, 2-port switch, 2*RJ45

1st interface

 

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

 

  • MPI

Yes

  • DP master

Yes

  • DP slave

Yes

  • Point-to-point connection

No

MPI

 

  • Transmission rate, max.

12 Mbit/s

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

Yes

    • S7 basic communication

Yes

    • S7 communication

Yes

    • S7 communication, as client

No; but via CP and loadable FB

    • S7 communication, as server

Yes

DP master

 

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

124

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

Yes; I blocks only

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes

    • Equidistance mode support

Yes

    • Isochronous mode

No

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Number of DP slaves that can be simultaneously activated/deactivated, max.

8

    • Direct data exchange (slave-to-slave communication)

Yes; As subscriber

    • DPV1

Yes

  • Address area

 

    • Inputs, max.

2 kbyte

    • Outputs, max.

2 kbyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

DP slave

 

  • Transmission rate, max.

12 Mbit/s

  • Automatic baud rate search

Yes; only with passive interface

  • Address area, max.

32

  • User data per address area, max.

32 byte

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes; Only with active interface

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes; Connection configured on one side only

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

No

  • Transfer memory

 

    • Inputs

244 byte

    • Outputs

244 byte

2nd interface

 

Interface type

PROFINET

Physics

Ethernet RJ45

Isolated

Yes

Integrated switch

Yes

Number of ports

2

Automatic detection of transmission speed

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Media redundancy

 

  • supported

Yes

  • Switchover time on line break, typically

200 ms; PROFINET MRP

  • Number of stations in the ring, max.

50

Functionality

 

  • MPI

No

  • DP master

No

  • DP slave

No

  • PROFINET IO Controller

Yes; Also simultaneously with IO-Device functionality

  • PROFINET IO Device

Yes; Also simultaneously with IO Controller functionality

  • PROFINET CBA

Yes

  • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • Web server

Yes

    • Number of HTTP clients

5

PROFINET IO Controller

 

  • Transmission rate, max.

100 Mbit/s

  • Number of connectable IO devices, max.

128

  • Max. number of connectable IO devices for RT

128

    • of which in line, max.

128

  • Number of IO devices with IRT and the option "high flexibility"

128

    • of which in line, max.

61

  • Number of IO Devices with IRT and the option "high performance", max.

64

    • of which in line, max.

64

  • IRT, supported

Yes

  • Shared device, supported

Yes

  • Prioritized startup supported

Yes

    • Number of IO Devices, max.

32

  • Activation/deactivation of IO Devices

Yes

    • Maximum number of IO devices that can be activated/deactivated at the same time.

8

  • IO Devices changing during operation (partner ports), supported

Yes

    • Max. number of IO devices per tool

8

  • Device replacement without swap medium

Yes

  • Send cycles

250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)

  • Updating time

250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • S7 communication

Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32

    • Isochronous mode

Yes; OB 61

    • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • Address area

 

    • Inputs, max.

2 kbyte

    • Outputs, max.

2 kbyte

    • User data consistency, max.

1 024 byte

PROFINET IO Device

 

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • S7 communication

Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32

    • Isochronous mode

No

    • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

    • IRT

Yes

    • PROFIenergy, supported

Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device

    • Shared device

Yes

    • Number of IO controllers with shared device, max.

2

  • Transfer memory

 

    • Inputs, max.

1 440 byte; Per IO Controller with shared device

    • Outputs, max.

1 440 byte; Per IO Controller with shared device

  • Submodules

 

    • Number, max.

64

    • User data per submodule, max.

1 024 byte

PROFINET CBA

 

  • acyclic transmission

Yes

  • Cyclic transmission

Yes

Open IE communication

 

  • Open IE communication, supported

Yes

  • Number of connections, max.

8

  • Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • Keep-alive function, supported

Yes

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFINET only

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes

Global data communication

 

  • supported

Yes

  • Number of GD loops, max.

8

  • Number of GD packets, max.

8

  • Number of GD packets, transmitter, max.

8

  • Number of GD packets, receiver, max.

8

  • Size of GD packets, max.

22 byte

  • Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

 

  • supported

Yes

  • User data per job, max.

76 byte

  • User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

 

  • supported

Yes

  • as server

Yes

  • As client

Yes

  • User data per job, max.

See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)

S5-compatible communication

 

  • supported

Yes; via CP and loadable FC

Open IE communication

 

  • TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length for connection type 01H, max.

1 460 byte

    • Data length for connection type 11H, max.

32 768 byte

    • Several passive connections per port, supported

Yes

  • ISO-on-TCP (RFC1006)

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length, max.

32 768 byte

  • UDP

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length, max.

1 472 byte

Web server

 

  • supported

Yes

  • Number of HTTP clients

5

  • User-defined websites

Yes

PROFINET CBA (at set setpoint communication load)

 

  • Setpoint for the CPU communication load

50 %

  • Number of remote interconnection partners

32

  • Number of functions, master/slave

30

  • Total of all Master/Slave connections

1 000

  • Data length of all incoming connections master/slave, max.

4 000 byte

  • Data length of all outgoing connections master/slave, max.

4 000 byte

  • Number of device-internal and PROFIBUS interconnections

500

  • Data length of device-internal und PROFIBUS interconnections, max.

4 000 byte

  • Data length per connection, max.

1 400 byte

  • Remote interconnections with acyclic transmission

 

    • Sampling frequency: Sampling time, min.

500 ms

    • Number of incoming interconnections

100

    • Number of outgoing interconnections

100

    • Data length of all incoming interconnections, max.

2 000 byte

    • Data length of all outgoing interconnections, max.

2 000 byte

    • Data length per connection, max.

1 400 byte

  • Remote interconnections with cyclic transmission

 

    • Transmission frequency: Transmission interval, min.

10 ms

    • Number of incoming interconnections

200

    • Number of outgoing interconnections

200

    • Data length of all incoming interconnections, max.

2 000 byte

    • Data length of all outgoing interconnections, max.

2 000 byte

    • Data length per connection, max.

450 byte

  • HMI variables via PROFINET (acyclic)

 

    • Number of stations that can log on for HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

    • HMI variable updating

500 ms

    • Number of HMI variables

200

    • Data length of all HMI variables, max.

2 000 byte

  • PROFIBUS proxy functionality

 

    • supported

Yes

    • Number of linked PROFIBUS devices

16

    • Data length per connection, max.

240 byte; Slave-dependent

Number of connections

 

  • overall

12

  • usable for PG communication

11

    • reserved for PG communication

1

    • Adjustable for PG communication, min.

1

    • Adjustable for PG communication, max.

11

  • usable for OP communication

11

    • reserved for OP communication

1

    • adjustable for OP communication, min.

1

    • adjustable for OP communication, max.

11

  • usable for S7 basic communication

8

    • Reserved for S7 basic communication

0

    • adjustable for S7 basic communication, min.

0

    • adjustable for S7 basic communication, max.

8

  • usable for S7 communication

10

    • reserved for S7 communication

0

    • Adjustable for S7 communication, min.

0

    • Adjustable for S7 communication, max.

10

  • Max. total number of instances

32

  • usable for routing

X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.

S7 message functions

 

Number of login stations for message functions, max.

12; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

 

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4

Status/control

 

  • Status/control variable

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

  • of which status variables, max.

30

  • of which control variables, max.

14

Forcing

 

  • Forcing

Yes

  • Force, variables

Inputs, outputs

  • Number of variables, max.

10

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

500

    • adjustable

No

    • Of which powerfail-proof

100; Only the last 100 entries are retained

  • Number of entries readable in RUN, max.

499

    • adjustable

Yes; From 10 to 499

    • preset

10

Service data

 

  • Can be read out

Yes

Interrupts/diagnostics/status information

 

Diagnostics indication LED

 

  • Status indicator digital output (green)

Yes

  • Status indicator digital input (green)

Yes

Integrated Functions

 

Number of counters

4; See "Technological Functions" manual

Counter frequency (counter) max.

60 kHz

Frequency measurement

Yes

Number of frequency meters

4; up to 60 kHz (see "Technological Functions" manual)

controlled positioning

Yes

Integrated function blocks (closed-loop control)

Yes; PID controller (see "Technological Functions" manual)

PID controller

Yes

Number of pulse outputs

4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)

Limit frequency (pulse)

2.5 kHz

Galvanic isolation

 

Galvanic isolation digital inputs

 

  • Galvanic isolation digital inputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Galvanic isolation digital outputs

 

  • Galvanic isolation digital outputs

Yes

  • between the channels

Yes

  • between the channels, in groups of

8

  • between the channels and the backplane bus

Yes

Galvanic isolation analog inputs

 

  • Galvanic isolation analog inputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Galvanic isolation analog outputs

 

  • Galvanic isolation analog outputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Permissible potential difference

 

between inputs and MANA (UCM)

8 V DC

between MANA and M internally (UISO)

75 VDC / 60 VAC

Ambient conditions

 

Operating temperature

 

  • Min.

0 °C

  • max.

60 °C

Configuration

 

Configuration software

 

  • STEP 7

Yes; V5.5 or higher

programming

 

  • Command set

see instruction list

  • Nesting levels

8

  • System functions (SFC)

see instruction list

  • System function blocks (SFB)

see instruction list

  • Programming language

 

    • LAD

Yes

    • FBD

Yes

    • STL

Yes

    • SCL

Yes

    • CFC

Yes

    • GRAPH

Yes

    • HiGraph®

Yes

Know-how protection

 

  • User program protection/password protection

Yes

  • Block encryption

Yes; With S7 block Privacy

Dimensions

 

Width

120 mm

Height

125 mm

Depth

130 mm

Weights

 

Weight, approx.

730 g

 